Go to The Journal of Clinical Investigation
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
  • Physician-Scientist Development
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Immunology
    • Metabolism
    • Nephrology
    • Oncology
    • Pulmonology
    • All ...
  • Videos
  • Collections
    • In-Press Preview
    • Resource and Technical Advances
    • Clinical Research and Public Health
    • Research Letters
    • Editorials
    • Perspectives
    • Physician-Scientist Development
    • Reviews
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • In-Press Preview
  • Resource and Technical Advances
  • Clinical Research and Public Health
  • Research Letters
  • Editorials
  • Perspectives
  • Physician-Scientist Development
  • Reviews
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
Identifying the third dimension in 2D fluoroscopy to create 3D cardiac maps
Jasbir Sra, … , Donald Brodnick, Daniel B. Rowe
Jasbir Sra, … , Donald Brodnick, Daniel B. Rowe
Published December 22, 2016
Citation Information: JCI Insight. 2016;1(21):e90453. https://doi.org/10.1172/jci.insight.90453.
View: Text | PDF
Research Article Cardiology

Identifying the third dimension in 2D fluoroscopy to create 3D cardiac maps

  • Text
  • PDF
Abstract

Three-dimensional cardiac mapping is important for optimal visualization of the heart during cardiac ablation for the treatment of certain arrhythmias. However, many hospitals and clinics worldwide cannot afford the high cost of the current mapping systems. We set out to determine if, using predefined algorithms, comparable 3D cardiac maps could be created by a new device that relies on data generated from single-plane fluoroscopy and patient recording and monitoring systems, without the need for costly equipment, infrastructure changes, or specialized catheters. The study included phantom and animal experiments to compare the prototype test device, Navik 3D, with the existing CARTO 3 System. The primary endpoint directly compared: (a) the 3D distance between the Navik 3D–simulated ablation location and the back-projected ground truth location of the pacing and mapping catheter electrode, and (b) the same distance for CARTO. The study’s primary objective was considered met if the 95% confidence lower limit was greater than 0.75% for the Navik 3D–CARTO difference between the 2 distances, or less than or equal to 2 mm. Study results showed that the Navik 3D performance was equivalent to the CARTO system, and that accurate 3D cardiac maps can be created using data from equipment that already exists in all electrophysiology labs.

Authors

Jasbir Sra, David Krum, Indrajit Choudhuri, Barry Belanger, Mark Palma, Donald Brodnick, Daniel B. Rowe

×

Figure 6

Navik 3D data flow diagram.

Options: View larger image (or click on image) Download as PowerPoint
Navik 3D data flow diagram.
Real-time patient data are acquired, process...
Real-time patient data are acquired, processed, recorded, and stored by the Navik 3D device. Orange reflects the flow of fluoroscopy image data, and green reflects the flow of signal data. The fluoroscopy and electrocardiogram-electrogram (ECG-EGM) data are synchronized and time stamped. The frame grabber for fluoroscopy data and analog-to-digital converter for ECG-EGM data are housed in the Main computer. A/D, analog to digital.

Copyright © 2025 American Society for Clinical Investigation
ISSN 2379-3708

Sign up for email alerts