Go to The Journal of Clinical Investigation
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
  • Physician-Scientist Development
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Immunology
    • Metabolism
    • Nephrology
    • Oncology
    • Pulmonology
    • All ...
  • Videos
  • Collections
    • In-Press Preview
    • Resource and Technical Advances
    • Clinical Research and Public Health
    • Research Letters
    • Editorials
    • Perspectives
    • Physician-Scientist Development
    • Reviews
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • In-Press Preview
  • Resource and Technical Advances
  • Clinical Research and Public Health
  • Research Letters
  • Editorials
  • Perspectives
  • Physician-Scientist Development
  • Reviews
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
mTORC1 is a mechanosensor that regulates surfactant function and lung compliance during ventilator-induced lung injury
Hyunwook Lee, Qinqin Fei, Adam Streicher, Wenjuan Zhang, Colleen Isabelle, Pragi Patel, Hilaire C. Lam, Antonio Arciniegas-Rubio, Miguel Pinilla-Vera, Diana P. Amador-Munoz, Diana Barragan-Bradford, Angelica Higuera-Moreno, Rachel K. Putman, Lynette M. Sholl, Elizabeth P. Henske, Christopher M. Bobba, Natalia Higuita-Castro, Emily M. Shalosky, R. Duncan Hite, John W. Christman, Samir N. Ghadiali, Rebecca M. Baron, Joshua A. Englert
Hyunwook Lee, Qinqin Fei, Adam Streicher, Wenjuan Zhang, Colleen Isabelle, Pragi Patel, Hilaire C. Lam, Antonio Arciniegas-Rubio, Miguel Pinilla-Vera, Diana P. Amador-Munoz, Diana Barragan-Bradford, Angelica Higuera-Moreno, Rachel K. Putman, Lynette M. Sholl, Elizabeth P. Henske, Christopher M. Bobba, Natalia Higuita-Castro, Emily M. Shalosky, R. Duncan Hite, John W. Christman, Samir N. Ghadiali, Rebecca M. Baron, Joshua A. Englert
View: Text | PDF
Research Article Pulmonology

mTORC1 is a mechanosensor that regulates surfactant function and lung compliance during ventilator-induced lung injury

  • Text
  • PDF
Abstract

The acute respiratory distress syndrome (ARDS) is a highly lethal condition that impairs lung function and causes respiratory failure. Mechanical ventilation (MV) maintains gas exchange in patients with ARDS but exposes lung cells to physical forces that exacerbate injury. Our data demonstrate that mTOR complex 1 (mTORC1) is a mechanosensor in lung epithelial cells and that activation of this pathway during MV impairs lung function. We found that mTORC1 is activated in lung epithelial cells following volutrauma and atelectrauma in mice and humanized in vitro models of the lung microenvironment. mTORC1 is also activated in lung tissue of mechanically ventilated patients with ARDS. Deletion of Tsc2, a negative regulator of mTORC1, in epithelial cells impairs lung compliance during MV. Conversely, treatment with rapamycin at the time MV is initiated improves lung compliance without altering lung inflammation or barrier permeability. mTORC1 inhibition mitigates physiologic lung injury by preventing surfactant dysfunction during MV. Our data demonstrate that, in contrast to canonical mTORC1 activation under favorable growth conditions, activation of mTORC1 during MV exacerbates lung injury and inhibition of this pathway may be a novel therapeutic target to mitigate ventilator-induced lung injury during ARDS.

Authors

Hyunwook Lee, Qinqin Fei, Adam Streicher, Wenjuan Zhang, Colleen Isabelle, Pragi Patel, Hilaire C. Lam, Antonio Arciniegas-Rubio, Miguel Pinilla-Vera, Diana P. Amador-Munoz, Diana Barragan-Bradford, Angelica Higuera-Moreno, Rachel K. Putman, Lynette M. Sholl, Elizabeth P. Henske, Christopher M. Bobba, Natalia Higuita-Castro, Emily M. Shalosky, R. Duncan Hite, John W. Christman, Samir N. Ghadiali, Rebecca M. Baron, Joshua A. Englert

×

Figure 7

mTORC1 activation exacerbates surfactant dysfunction during injurious ventilation.

Options: View larger image (or click on image) Download as PowerPoint
mTORC1 activation exacerbates surfactant dysfunction during injurious ve...
(A) Total phospholipid levels were measured in mice treated with veh or rapa (5 mg/kg) following 4 hours of injurious ventilation (TV 12 cc/kg, PEEP 0 cm H2O). Data normally distributed, analyzed by Student’s t test. Phospholipid levels were also measured in LA fractions (B) and SA fractions (C). (A–C) Data normally distributed, analyzed by Student’s t test, n = 16 for veh and n = 18 for rapa. (D) The ratio of LA/SA phospholipid was calculated (n = 15 veh, n = 18 rapa). (E) Minimum surface tension after 15 cycles measured using a CDS in LA fractions from vehicle- and rapamycin-treated mice. Data not normally distributed, analyzed by Mann-Whitney test, n = 15 veh, n = 18 rapa. (F and G) Representative images of minimum surface tension from LA fractions of mice treated with rapa or veh prior to VILI. Total (H), LA (I), and SA (J) phospholipid levels were measured in mice with airway epithelial Tsc2 deletion (Cre+) and Cre– control mice following 4 hours of injurious ventilation (TV 12 cc/kg, PEEP 0 cm H2O). The ratio of LA/SA phospholipid was calculated (K). Data normally distributed, analyzed by Student’s t test, n = 20/group for (H–K). (L) Minimum surface tension after 25 cycles measured using CDS in LA fractions from Cre- and Cre+ mice. Data log normally distributed, analyzed by Student’s t test on log2 transformed data, n = 19/group. (M and N) representative images of minimum surface tension from LA fractions of Cre- and Cre+ mice following VILI. Box blots show median ± interquartile range and whiskers define min and max values. *P < 0.05.

Copyright © 2025 American Society for Clinical Investigation
ISSN 2379-3708

Sign up for email alerts