Go to The Journal of Clinical Investigation
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
  • Physician-Scientist Development
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Immunology
    • Metabolism
    • Nephrology
    • Oncology
    • Pulmonology
    • All ...
  • Videos
  • Collections
    • In-Press Preview
    • Resource and Technical Advances
    • Clinical Research and Public Health
    • Research Letters
    • Editorials
    • Perspectives
    • Physician-Scientist Development
    • Reviews
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • In-Press Preview
  • Resource and Technical Advances
  • Clinical Research and Public Health
  • Research Letters
  • Editorials
  • Perspectives
  • Physician-Scientist Development
  • Reviews
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
Continuous vestibular implant stimulation partially restores eye-stabilizing reflexes
Peter J. Boutros, Desi P. Schoo, Mehdi Rahman, Nicolas S. Valentin, Margaret R. Chow, Andrianna I. Ayiotis, Brian J. Morris, Andreas Hofner, Aitor Morillo Rascon, Andreas Marx, Ross Deas, Gene Y. Fridman, Natan S. Davidovics, Bryan K. Ward, Carolina Treviño, Stephen P. Bowditch, Dale C. Roberts, Kelly E. Lane, Yoav Gimmon, Michael C. Schubert, John P. Carey, Andreas Jaeger, Charles C. Della Santina
Peter J. Boutros, Desi P. Schoo, Mehdi Rahman, Nicolas S. Valentin, Margaret R. Chow, Andrianna I. Ayiotis, Brian J. Morris, Andreas Hofner, Aitor Morillo Rascon, Andreas Marx, Ross Deas, Gene Y. Fridman, Natan S. Davidovics, Bryan K. Ward, Carolina Treviño, Stephen P. Bowditch, Dale C. Roberts, Kelly E. Lane, Yoav Gimmon, Michael C. Schubert, John P. Carey, Andreas Jaeger, Charles C. Della Santina
View: Text | PDF
Clinical Research and Public Health Neuroscience Otology

Continuous vestibular implant stimulation partially restores eye-stabilizing reflexes

  • Text
  • PDF
Abstract

BACKGROUND Bilateral loss of vestibular (inner ear inertial) sensation causes chronically blurred vision during head movement, postural instability, and increased fall risk. Individuals who fail to compensate despite rehabilitation therapy have no adequate treatment options. Analogous to hearing restoration via cochlear implants, prosthetic electrical stimulation of vestibular nerve branches to encode head motion has garnered interest as a potential treatment, but prior studies in humans have not included continuous long-term stimulation or 3D binocular vestibulo-ocular reflex (VOR) oculography, without which one cannot determine whether an implant selectively stimulates the implanted ear’s 3 semicircular canals.METHODS We report binocular 3D VOR responses of 4 human subjects with ototoxic bilateral vestibular loss unilaterally implanted with a Labyrinth Devices Multichannel Vestibular Implant System vestibular implant, which provides continuous, long-term, motion-modulated prosthetic stimulation via electrodes in 3 semicircular canals.RESULTS Initiation of prosthetic stimulation evoked nystagmus that decayed within 30 minutes. Stimulation targeting 1 canal produced 3D VOR responses approximately aligned with that canal’s anatomic axis. Targeting multiple canals yielded responses aligned with a vector sum of individual responses. Over 350–812 days of continuous 24 h/d use, modulated electrical stimulation produced stable VOR responses that grew with stimulus intensity and aligned approximately with any specified 3D head rotation axis.CONCLUSION These results demonstrate that a vestibular implant can selectively, continuously, and chronically provide artificial sensory input to all 3 implanted semicircular canals in individuals disabled by bilateral vestibular loss, driving reflexive VOR eye movements that approximately align in 3D with the head motion axis encoded by the implant.TRIAL REGISTRATION ClinicalTrials.gov: NCT02725463.FUNDING NIH/National Institute on Deafness and Other Communication Disorders: R01DC013536 and 2T32DC000023; Labyrinth Devices, LLC; and Med-El GmbH.

Authors

Peter J. Boutros, Desi P. Schoo, Mehdi Rahman, Nicolas S. Valentin, Margaret R. Chow, Andrianna I. Ayiotis, Brian J. Morris, Andreas Hofner, Aitor Morillo Rascon, Andreas Marx, Ross Deas, Gene Y. Fridman, Natan S. Davidovics, Bryan K. Ward, Carolina Treviño, Stephen P. Bowditch, Dale C. Roberts, Kelly E. Lane, Yoav Gimmon, Michael C. Schubert, John P. Carey, Andreas Jaeger, Charles C. Della Santina

×
Problems with a PDF?

This file is in Adobe Acrobat (PDF) format. If you have not installed and configured the Adobe Acrobat Reader on your system.

Having trouble reading a PDF?

PDFs are designed to be printed out and read, but if you prefer to read them online, you may find it easier if you increase the view size to 125%.

Having trouble saving a PDF?

Many versions of the free Acrobat Reader do not allow Save. You must instead save the PDF from the JCI Online page you downloaded it from. PC users: Right-click on the Download link and choose the option that says something like "Save Link As...". Mac users should hold the mouse button down on the link to get these same options.

Having trouble printing a PDF?

  1. Try printing one page at a time or to a newer printer.
  2. Try saving the file to disk before printing rather than opening it "on the fly." This requires that you configure your browser to "Save" rather than "Launch Application" for the file type "application/pdf", and can usually be done in the "Helper Applications" options.
  3. Make sure you are using the latest version of Adobe's Acrobat Reader.

ICMJE disclosure forms - Download (347.53 KB)

Advertisement

Copyright © 2026 American Society for Clinical Investigation
ISSN 2379-3708

Sign up for email alerts