Go to The Journal of Clinical Investigation
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Transfers
  • Advertising
  • Job board
  • Contact
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Immunology
    • Metabolism
    • Nephrology
    • Oncology
    • Pulmonology
    • All ...
  • Videos
  • Collections
    • Resource and Technical Advances
    • Clinical Medicine
    • Reviews
    • Editorials
    • Perspectives
    • Top read articles
  • JCI This Month
    • Current issue
    • Past issues

  • Current issue
  • Past issues
  • Specialties
  • In-Press Preview
  • Editorials
  • Viewpoint
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Transfers
  • Advertising
  • Job board
  • Contact

Usage Information

New insights on glomerular hyperfiltration: a Japanese autopsy study
Go Kanzaki, … , Takashi Yokoo, John F. Bertram
Go Kanzaki, … , Takashi Yokoo, John F. Bertram
Published October 5, 2017
Citation Information: JCI Insight. 2017;2(19):e94334. https://doi.org/10.1172/jci.insight.94334.
View: Text | PDF
Clinical Medicine Nephrology

New insights on glomerular hyperfiltration: a Japanese autopsy study

  • Text
  • PDF
Abstract

It has been suggested that low nephron number contributes to glomerular hypertension and hyperperfusion injury in progressive chronic kidney disease (CKD). The incidence of CKD in Japan is among the highest in the world, but the reasons remain unclear. We estimated total nephron (glomerular) number (NglomTOTAL) as well as numbers of nonsclerosed (NglomNSG) and globally sclerosed glomeruli (NglomGSG), and the mean volume of nonsclerosed glomeruli (VglomNSG) in Japanese normotensive, hypertensive, and CKD subjects and investigated associations between these parameters and estimated glomerular filtration rate (eGFR). Autopsy kidneys from age-matched Japanese men (9 normotensives, 9 hypertensives, 9 CKD) had nephron number and VglomNSG estimated using disector/fractionator stereology. Subject eGFR, single-nephron eGFR (SNeGFR), and the ratio SNeGFR/VglomNSG were calculated. NglomNSG in Japanese with hypertension (392,108 ± 87,605; P < 0.001) and CKD (268,043 ± 106,968; P < 0.001) was less than in normotensives (640,399 ± 160,016). eGFR was directly correlated with NglomNSG (r = 0.70, P < 0.001) and inversely correlated with VglomNSG (r = –0.53, P < 0.01). SNeGFR was higher in hypertensives than normotensives (P = 0.03), but was similar in normotensives and CKD, while the ratio SNeGFR/VglomNSG was similar in normotensives and hypertensives but markedly reduced in CKD. Nephron number in Japanese with hypertension or CKD was low. This results in a higher SNeGFR in hypertensives compared with normotensive and CKD subjects, but lowered SNeGFR/VglomNSG in CKD subjects, suggesting that changes in GFR are accommodated by glomerular hypertrophy rather than glomerular hypertension. These findings suggest glomerular hypertrophy is a dominant factor in maintenance of GFR under conditions of low nephron number.

Authors

Go Kanzaki, Victor G. Puelles, Luise A. Cullen-McEwen, Wendy E. Hoy, Yusuke Okabayashi, Nobuo Tsuboi, Akira Shimizu, Kate M. Denton, Michael D. Hughson, Takashi Yokoo, John F. Bertram

×

Usage data is cumulative from March 2022 through March 2023.

Usage JCI PMC
Text version 1,308 135
PDF 288 111
Figure 309 1
Table 802 0
Citation downloads 64 0
Totals 2,771 247
Total Views 3,018
(Click and drag on plot area to zoom in. Click legend items above to toggle)

Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.

Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.

Advertisement

Copyright © 2023 American Society for Clinical Investigation
ISSN 2379-3708

Sign up for email alerts