[HTML][HTML] A perivascular system releasing sirolimus prevented intimal hyperplasia in a rabbit model in a medium-term study

I Skalský, O Szárszoi, E Filová, M Pařízek… - International journal of …, 2012 - Elsevier
I Skalský, O Szárszoi, E Filová, M Pařízek, A Lytvynets, J Malušková, A Lodererová…
International journal of pharmaceutics, 2012Elsevier
The main complication of aortocoronary reconstruction with vein grafts is restenosis in the
course of time. The aim was to assess the effect of a periadventitial polyester mesh releasing
sirolimus on intimal hyperplasia of autologous grafts. We implanted v. jugularis ext. into a.
carotis communis in rabbits. The vein graft was either intact, or was wrapped with a pure
polyester mesh, or with a sirolimus-releasing mesh. Three and six weeks after surgery, the
veins were subjected to standard histological staining and the thicknesses of the tunica …
The main complication of aortocoronary reconstruction with vein grafts is restenosis in the course of time. The aim was to assess the effect of a periadventitial polyester mesh releasing sirolimus on intimal hyperplasia of autologous grafts. We implanted v. jugularis ext. into a. carotis communis in rabbits. The vein graft was either intact, or was wrapped with a pure polyester mesh, or with a sirolimus-releasing mesh. Three and six weeks after surgery, the veins were subjected to standard histological staining and the thicknesses of the tunica intima, the media and the intima–media complex were measured. Wrapping the vein with a mesh releasing sirolimus or with a pure mesh decreased the thickness of the intima in comparison with a vein graft by 73±11% or 73±8% after 3weeks, and by 73±9% or 59±12% after 6weeks, respectively. Sirolimus-releasing meshes reduced the thickness of the media by 65±9% and 20±12% after 3 and 6weeks. The thickness of the intima–media complex in grafts with sirolimus-releasing meshes decreased by 60±6% and 30±13% in comparison with pure PES meshes, after 3 and 6weeks, respectively. A periadventitial polyester mesh releasing sirolimus has the potential to become an effective device in preventing vein graft restenosis.
Elsevier