Go to The Journal of Clinical Investigation
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
  • Physician-Scientist Development
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Immunology
    • Metabolism
    • Nephrology
    • Oncology
    • Pulmonology
    • All ...
  • Videos
  • Collections
    • In-Press Preview
    • Resource and Technical Advances
    • Clinical Research and Public Health
    • Research Letters
    • Editorials
    • Perspectives
    • Physician-Scientist Development
    • Reviews
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • In-Press Preview
  • Resource and Technical Advances
  • Clinical Research and Public Health
  • Research Letters
  • Editorials
  • Perspectives
  • Physician-Scientist Development
  • Reviews
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
Heterogeneity of the action potential duration is required for sustained atrial fibrillation
Uma Mahesh R. Avula, Jeffrey Abrams, Alexander Katchman, Sergey Zakharov, Sergey Mironov, Joseph Bayne, Daniel Roybal, Anirudh Gorti, Lin Yang, Vivek Iyer, Marc Waase, Deepak Saluja, Edward J. Ciaccio, Hasan Garan, Andrew R. Marks, Steven O. Marx, Elaine Y. Wan
Uma Mahesh R. Avula, Jeffrey Abrams, Alexander Katchman, Sergey Zakharov, Sergey Mironov, Joseph Bayne, Daniel Roybal, Anirudh Gorti, Lin Yang, Vivek Iyer, Marc Waase, Deepak Saluja, Edward J. Ciaccio, Hasan Garan, Andrew R. Marks, Steven O. Marx, Elaine Y. Wan
View: Text | PDF
Research Article Cardiology Cell biology

Heterogeneity of the action potential duration is required for sustained atrial fibrillation

  • Text
  • PDF
Abstract

Atrial fibrillation (AF) is the most common cardiac arrhythmia and accounts for substantial morbidity and mortality. Recently, we created a mouse model with spontaneous and sustained AF caused by a mutation in the NaV1.5 channel (F1759A) that enhances persistent Na+ current, thereby enabling the investigation of molecular mechanisms that cause AF and the identification of potentially novel treatment strategies. The mice have regional heterogeneity of action potential duration of the atria similar to observations in patients with AF. In these mice, we found that the initiation and persistence of the rotational reentrant AF arrhythmias, known as spiral waves or rotors, were dependent upon action potential duration heterogeneity. The centers of the rotors were localized to regions of greatest heterogeneity of the action potential duration. Pharmacologically attenuating the action potential duration heterogeneity reduced both spontaneous and pacing-induced AF. Computer-based simulations also demonstrated that the action potential duration heterogeneity is required to generate rotors that manifest as AF. Taken together, these findings suggest that action potential duration heterogeneity in mice and humans is one mechanism by which AF is initiated and that reducing action potential duration heterogeneity can lessen the burden of AF.

Authors

Uma Mahesh R. Avula, Jeffrey Abrams, Alexander Katchman, Sergey Zakharov, Sergey Mironov, Joseph Bayne, Daniel Roybal, Anirudh Gorti, Lin Yang, Vivek Iyer, Marc Waase, Deepak Saluja, Edward J. Ciaccio, Hasan Garan, Andrew R. Marks, Steven O. Marx, Elaine Y. Wan

×

Figure 4

Triggered activity is required for initiation and perpetuation of AF in F1759A-dTG mice.

Options: View larger image (or click on image) Download as PowerPoint
Triggered activity is required for initiation and perpetuation of AF in ...
(A) Isochronal map of atrial-paced beat and first triggered beat. (B) Electrogram shows triggered beats after atrial pacing at 10 Hz. Scale bar: 1 mm. (C and D) Time-space plots of LA and left ventricle (LV) during 10-Hz atrial pacing. EADs are marked by asterisks. Horizontal scale bar: 500 ms. Vertical scale bar: 2.5 mm. Single-pixel electrograms (D) showing EADs and rotor. Scale bar: 100 ms. (E) APD50 map of Langendorff-perfused F1759A-dTG heart after conversion to sinus rhythm before (vehicle) and after 3 μM SEA-0400. Scale bar: 1 mm. (F) Graph depicting relationship between APD and APD dispersion before (vehicle) and after SEA-0400 perfusion. n = 3. P = 0.37 by 2-tailed Student’s t test. (G and H) Time-space plots of LA and LV during 10-Hz atrial pacing after SEA-0400. Horizontal scale bar: 500 ms. Vertical scale bar: 2.5 mm. Single-pixel electrograms (H) showing normal rhythm without EADs or rotors. (I) Graph depicting relationship between number of EADs/min and percentage of EADs causing AF before (vehicle) and after SEA-0400 perfusion. n = 3. P < 0.05 by 2-tailed Student’s t test for both EADs/min and percentage of EADs causing AF.

Copyright © 2026 American Society for Clinical Investigation
ISSN 2379-3708

Sign up for email alerts